White Towel Radiator Technical Specifications
Usage Details
White towel radiators are designed to be used for both heating and towel drying purposes in bathroom, hotel, residence, villa, and project applications. Thanks to its steel body structure and electrostatic powder paint coating, it offers durability, aesthetics, and long-lasting use.
The products are suitable for use in central heating systems and closed circuit radiator installations. Different size options allow them to be preferred for various applications from small bathrooms to large project areas.
Installation Details
Towel radiator installation must be done by securely fastening it to the wall according to the connection points of the installation. Before installation, the product size, connection spacing, and installation exit points should be checked.
Things to Consider During Installation:

Chrome Towel Radiator Technical Specifications
Usage Details
Chrome towel radiators are used for both heating and towel drying purposes in bathroom, hotel, residence, and decorative project applications. Thanks to its shiny chrome surface, it adds a more elegant, modern, and decorative look to bathrooms.
Chrome surface products are particularly preferred in hotels, villas, residences, and special projects where aesthetic appearance is emphasized. They are suitable for use in closed circuit central heating systems.
Installation Details
Chrome towel radiator installation must be done by securely fastening it to the wall according to the connection points of the installation. During installation, care must be taken to avoid scratching the chrome surface, and the protective packaging should be maintained as much as possible until the installation stage.
Things to Consider During Installation:

Colored Towel Radiator Technical Specifications
Usage Details
Colored towel radiators are used for both heating and towel drying purposes in bathroom, hotel, residence, villa, and decorative project applications. Thanks to different color options, they adapt to interior architectural designs and create a modern, stylish, and decorative look in bathrooms.
The surface durability is increased thanks to the electrostatic powder paint coating. Colored models are especially preferred in residential, hotel, apartment, and project applications where requests for anthracite, black, gray, gold, and special colors are present.
Installation Details
Colored towel radiator installation must be done by securely fastening it to the wall according to the connection points of the installation. Care should be taken during installation to avoid scratching the painted surface.
Things to Consider During Installation:

Oval Towel Radiator Technical Specifications
Usage Details
Oval towel radiator provides an aesthetic appearance, reliable heating performance, and comfortable use for modern bathrooms and decorative project applications. Its design with oval lines offers a softer and more decorative appearance compared to standard towel radiator models.
It can be used for both room heating and towel drying purposes in bathrooms, hotels, residences, villas, and special projects. It adapts to interior architectural designs with different color and coating options.
Installation Details
Oval towel radiator installation must be done by securely fastening it to the wall according to the connection points of the installation. Before installation, the product size, connection spacing, and installation exit points should be checked.
Things to Consider During Installation:

Stove_Cooker_Oven Connection Flexes Technical Specifications
Usage Details
Cooker flexes are flexible connection hoses used to securely connect devices such as natural gas stoves, cookers, and ovens to gas installations. Their flexible structure provides ease during installation and helps establish a more orderly connection between the device and the installation.
Thanks to its 316 L stainless steel structure, it offers durability. Stove flexes manufactured in accordance with TS EN 14800 standard can be preferred in residential kitchens, commercial kitchens, project applications, and natural gas installation connections.
The product should only be used for gas installation connections. It should not be used for water, steam, chemical fluids, or for any other purposes.
Installation Details
Stove flex installation must be performed by authorized and expert personnel in the field of gas installations. Before installation, the product length, connection measurements, installation exit, and device connection points should be checked.
The flex hose should be connected in the proper position between the device and the fixed installation; it should not experience twisting, crushing, or excessive tension. After completing the connection, sealing check should be performed, and gas leak must be assured.
Things to Consider During Installation

Combi_Water Heater (With Corrugation) Connection Flexes Technical Specifications
Usage Details
Combi and water heater flexes are flexible connection hoses used to safely and practically connect combi and water heater devices to natural gas installations.
Its flexible body structure provides ease during installation and helps establish a more organized connection between the device and the fixed gas installation. With its 316 L stainless steel hose structure and protective corrugated coating, it offers durability.
Combi and water heater connection flexes produced in accordance with TS EN 13890 standard can be used in housing, apartments, villas, commercial areas, and project applications.
The product should only be used in natural gas installation connections. It should not be used for water, steam, chemical fluids, or different purposes.
Installation Details
Installation for combi and water heater flexes must be performed by authorized and expert personnel in the field of gas installations. Before installation, the product length, connection measurements, installation outlet, and device connection points should be checked.
The flex hose should be connected in the proper position between the fixed gas installation and the combi or water heater device. During installation, the hose should not experience twisting, crushing, excessive bending, or tension.
After completing the connection, sealing check should be performed, and gas leak must be assured.
Things to Consider During Installation

G4 Meter (With Corrugation) Connection Flexes Technical Specifications
Usage Details
G4 meter flexes are flexible connection hoses used to securely and practically connect G4 natural gas meters to fixed gas installations.
The flexible body structure provides convenience during installation and helps to create a more organized connection between the meter and the installation. With its 316 L stainless steel hose structure and protective corrugated coating, it offers durability.
Produced in accordance with TS EN 13890 standard, meter connection flexes can be used in housing, apartments, small offices, low-capacity commercial areas, and project applications.
The product should only be used for natural gas meter connections. It should not be used for water, steam, chemical fluids, or differing purposes.
Installation Details
Installation for G4 meter flexes must be performed by authorized and expert personnel in the field of gas installations. Before installation, the meter type, connection measurements, installation outlet, and product compatibility should be checked.
The flex hose should be connected in the proper position between the natural gas meter and the fixed gas installation. During installation, the hose should not experience twisting, crushing, excessive bending, or tension.
After completing the connection, sealing checks should be performed, and gas leakage must be assured.
Things to Consider During Installation